Voltage
10 - 30Vdc
Current
250mA @12Vdc - 130mA @24Vdc
Solenoids
Solenoid rated for continuous use
Electrical protection
Polarity and back EMF protected
Monitoring
Solenoid Monitor - 1 amp NO/NC microswitch
Door / Latch Monitor - 1 amp NO/NC microswitch
Holding force
1300kg static strength rating
Endurance
1,200,000 cycles endurance rating @ 25kg pre-load
2,500,000 cycles general durability without pre-load conditions
Latching
Suitable for 15mm latch with 3mm door gap
Environment
Operational temperature range - 20C to +60C
Body
Solid Stainless Steel Construction
Keeper
Stainless Steel
Specification Statement
The electric strike should be fully monitored and have independent door / latch and solenoid monitor switches. Holding force for the strike should be not less than 1300kg.
Where Power to Lock and Power to Open functions may be required in the same building, a single electric strike should be interchangeable from either fail safe or fail secure from the rear of the strike.
The electric strike should not consume current greater than 250mA @ 12Vdc and have a solenoid rated for continuous use. A fire rating not less than 4 hours is required where applicable. The strike must be capable of operating with up to 25kg of pre-load pressure applied to the keeper, be tested to 2.5 million operations and carry a minimum warranty of 5 years.
_________________________________________________________
Dimensions