Lockwood Padde Series ES9000 Pre-Load Electric strike NO LIP
The ES9000 electric strike is a high security product manufactured from solid stainless steel and designed to be used on special application doors that require access control.
4 hour fire rating. And Australian Government listed.
The ES9000 is designed, developed and manufactured in Melbourne.

Approved for Security Level 3
ES9000 - Pre-load (side pressure) testing
The ES9000 overcomes the real life issue of side pressure, commonly known as pre-load, easily opening with up to 25kg of pre-load applied to the strike. Pre-load is commonly caused by pulling on a door before it unlocks, by the weight of warped or drooping doors or by differential air pressure created by heating and cooling systems.
Standard features include multi voltage 10 - 30Vdc and field changeable settings from fail safe to fail secure.
Built to last, this is a premium locking solution that has been tested in excess of 2 million cycles and boasts unique features like no other available on the market today.
Applications
Standards and Compliance
Voltage
10 - 30Vdc
Current
250mA @12Vdc - 130mA @24Vdc
Solenoids
Solenoid rated for continuous use
Electrical protection
Polarity and back EMF protected
Monitoring
Solenoid Monitor - 1 amp NO/NC microswitch
Door / Latch Monitor - 1 amp NO/NC microswitch
Holding force
1300kg static strength rating
Endurance
1,200,000 cycles endurance rating @ 25kg pre-load
2,500,000 cycles general durability without pre-load conditions
Latching
Suitable for 15mm latch with 3mm door gap
Environment
Operational temperature range - 20C to +60C
Body
Solid Stainless Steel Construction
Keeper
Stainless Steel
Specification Statement
The electric strike should be fully monitored and have independent door / latch and solenoid monitor switches. Holding force for the strike should be not less than 1300kg.
Where Power to Lock and Power to Open functions may be required in the same building, a single electric strike should be interchangeable from either fail safe or fail secure from the rear of the strike.
The electric strike should not consume current greater than 250mA @ 12Vdc and have a solenoid rated for continuous use. A fire rating not less than 4 hours is required where applicable. The strike must be capable of operating with up to 25kg of pre-load pressure applied to the keeper, be tested to 2.5 million operations and carry a minimum warranty of 5 years.
How long will this item take to arrive?
Click HERE to see our dispatch timeframes ➔
We offer local installation services in Melbourne's eastern suburbs
View local installation areas ➔